This topic describes how to establish a dedicated Direct Connect (DC) connection.
Before you begin
Procedure
Step 1: Create DC Connection
- In the top menu bar, select a target region and project.
- Click Create DC Connection.
- Configure the DC Connection port based on the table below.
- This example demonstrates only sample values for required parameters. For more parameter details, see Creating a Direct Connect Connection. Sample values are for reference only and have no practical significance.
- After configuration, click Buy now to submit the application.
Step 2: Apply for LOA
LOA is a letter of authorization for the DC Connection construction in the VolcanoEngine access point data center. After the DC Connection application is approved, the status of DC Connection becomes LOA pending. Go to the VolcanoEngine DC Connection console to apply for the LOA.
- In the top menu bar, select China (Beijing).
- In the DC Connection list, click Apply for LOA to the right of the DC connection (DAS123_port308_conn), and configure the LOA application based on the table below.
- Click Submit to complete the application submission and wait for LOA review.
Step 3: Construction by Line Operator
- After the LOA application is approved, the DC Connection status becomes Line operator construction. Click Download LOA in the Actions column to the right of the target DC Connection to obtain the LOA for on-site construction.
- You should take the LOA with you, and contact the Line Operator to construct the DC connection in the VolcanoEngine access point data center.
Step 4: Report completion
After the Line Operator completes the construction and you finalize the completion by testing the DC Connection link connectivity, you need to access the VolcanoEngine DC Connection console to report the completion.
- In the top menu bar, select China (Beijing).
- In the DC Connection list, click Completion report in the Actions column to the right of DAS123_port308_conn.
- After confirming the information about the DC Connection to report, enter the Building Cable ID of the DC access point's data center.
To this point, the status of DAS123_port308_conn changes to VolcanoEngine construction.
Step 5: Construction by VolcanoEngine
After the completion report is submitted, VolcanoEngine engineers will perform patch cord installation and check optical attenuation for your DC Connection. You will receive a notification via onsite message and SMS once the construction is complete. Wait patiently.
Step 6: Pay port occupancy fee
- In the top menu bar, select China (Beijing).
- In the DC Connection list, click Pay now in the Actions column to the right of DAS123_port308_conn.
- Follow the guidance to complete the payment. After payment, the status of DAS123_port308_conn becomes Opened.
What to do next