Alarm notification content
View alarm execution results
Copy page
Download PDF
View alarm execution results
The TLS console displays detailed information for all alarm policies, including basic policy information, monitoring details, and execution data for each alarm policy.​
View policy details​
The alarm policy list shows the policy name, ID, current application status, and information about the monitored Topic objects. Click the alarm policy name to access the policy details tab, where you can view basic information, monitoring details, and alarm information.​
  • In the basic information section, you can enable or disable the current alarm policy directly.​
  • If the alarm policy does not meet current business monitoring and alarm requirements, click Edit in the upper right corner to modify the policy.​
View execution details​
The execution information tab uses a built-in dashboard to display recent alarm policy execution status. The dashboard displays execution data from the last 30 minutes by default, including the following charts:​
​
Chart​
Description​
Number of alarms​
The number of times the monitoring task was successfully executed according to the specified execution cycle. For example, TLS executes a query and analysis statement every 15 minutes based on the alarm policy, and checks whether it meets the trigger conditions and sending cycle requirements. If the alarm monitoring was executed 10 times, the number of alarms is 10.​
Success rate of execution​
The percentage of monitoring tasks that were successfully sent or partially succeeded out of all alarm monitoring tasks executed.​
For example, TLS executes the query and analysis statement every 15 minutes based on the alarm policy, checking whether trigger conditions and sending cycles are met. If 10 alarm monitoring tasks are executed and only one alarm notification is triggered and sent successfully, the success rate is 10%.​
Alarm trigger trends​
The trend of alarm policy trigger counts over time.​
Alarm history​
Execution history of alarm policy monitoring tasks. For more details, see the table below.​
You can also click View details in the last column to go to the query and analysis page of the corresponding log topic and review the results of the monitoring task.​
​
The fields of Alarm history are described as follows.​
​
Display item​
Description​
Execution time​
Execution time for the current alarm policy's monitoring task.​
Notification status​
Whether the alarm notification has been sent.​
  • All sent successfully: Alarm notifications were successfully sent to the corresponding notification group.​
  • Partially sent successfully: Alarm notifications have been sent to the corresponding notification groups. However, some users were not reached due to issues such as inaccessible notification channels or no configuration to receive alarm of the corresponding type.​
  • Failed to send: Failed to send alarm notification.​
  • Not sent: Alarm notification was not sent. Determine the specific reason based on the execution result.​
Execution result​
The execution result for this task. For more details, see Execution result description.​
Details​
Describes the details of the specified result, helping identify the specific cause of the issue.​
Trigger condition​
The trigger condition configured in the alarm policy, expressed as a formula.​
Monitored object​
The monitored Topic name.​
Alarm group​
The notification group for the alarm policy.​
View details​
Go to the query and analysis page for the target log topic to view the query and analysis statement you set in the current alarm policy and its result.​
​
Execution result description​
The types and descriptions of alarm execution results are as follows.​
​
Execution result​
Description​
Alarm policy configuration is missing. Check whether the alarm policy and monitored objects are properly configured.​
No alarm policy configured.​
Check whether the alarm policy and monitored objects are properly configured.​
The analysis statement for the monitored object contains syntax errors. Please review the statement for correctness. For proper syntax, refer to analysis statement.​
The analysis statement for the monitored object contains query or analysis syntax errors.​
Check whether the syntax is correct according to the Query syntaxdocumentation and Log analysis guidelines.​
Exception exists in analysis statement execution. Check your analysis statement and the index configuration for the log topic.​
Failed to execute the analysis statement due to an exception.​
You can refer to the documentation Query syntax and Log analysisto check if the syntax is correct, and verify that the index is configured properly.​
Failed to parse the format of the analysis result.​
Failed to parse the format of the analysis result.​
You can refer to the documentation Query syntax and Log analysis to check if the syntax is correct.​
The alarm trigger conditions are met, but the alarm convergence threshold is not reached, so the alarm notification will not be sent: The cycle convergence condition is not met, for example, the alarm triggers after persisting for 5 monitoring cycles: The alarm interval condition is not met, for example, an alarm is triggered every 15 minutes.​
Alarm trigger conditions are met, but do not comply with the alarm notification cycle requirement, so the notification is not sent. For example:​
  • The monitoring cycle requirement for the alarm is not met. For instance, the alarm requires five consecutive monitoring cycles to trigger, but the current monitoring has persisted for only one cycle.​
  • The alarm interval requirement is not met. For example, the alarm requires a notification to be sent every 15 minutes, but only 5 minutes have passed since the last alarm notification.​
The alarm notification types (alarm notification, alarm recovery) do not match the notification template.​
The alarm notification types (alarm notification, alarm recovery) do not match the notification group settings, so no alarm notification is sent.​
The alarm notification time period does not match the notification template.​
The alarm trigger time does not match the alarm notification time period specified by the notification group, so no alarm notification is sent.​
Failed to send notification.​
Due to frequency control restrictions of the notification channel and other reasons, TLS attempted to send an alarm notification but failed.​
The alarm conditions are met and notification was sent successfully.​
Alarm sent successfully.​
Internal service error. Failed to execute alarm.​
The alarm monitoring task failed to execute due to internal reasons.​
Trigger conditions not met​
The analysis results for the current monitoring period do not meet the alarm trigger conditions.​
Partial alarms sent successfully​
Alarm notifications were successfully sent through some channels.​
Syntax error in alarm conditions.​
Syntax error in the alarm trigger condition expression.​
We recommend using the alarm test feature to debug your expression and confirming its accuracy before enabling the alarm policy.​
Expression calculation error in alarm.​
Failed to execute the trigger condition expression.​
We recommend checking whether the analysis results contain variables referenced by the trigger condition expression.​
Result type error in alarm expression​
The result of the trigger condition is not a Boolean value, so it can not determine whether to trigger an alarm based on the trigger condition.​
Check whether the trigger condition expression is correct.​
​
​