You need to enable JavaScript to run this app.
Torch Object Storage

Torch Object Storage

Copy page
Download PDF
07-LIFECYCLE
0007-00000501
Copy page
Download PDF
0007-00000501
Problem description​
The NoncurrentVersionTransitions field in the configured lifecycle rule has an invalid StorageClass parameter value.​
Root cause​
The NoncurrentVersionTransition field in the configured lifecycle rule has an invalid StorageClass parameter value.​
Example​
​
{​
"Rules": [{​
"ID": "id",​
"Prefix": "prefix",​
"Status": "Enabled",​
"NoncurrentVersionTransition": [​
{​
"StorageClass": "STANDARD-IA",​
"NoncurrentDays": 30​
}​
]​
}]​
}​
​
Solution​
The StorageClass parameter values configured in the NoncurrentVersionTransitions field are as follows:​
  • IA: Infrequent Access storage.​
  • INTELLIGENT_TIERING: Intelligent tiered storage.​
  • ARCHIVE_FR: archive flashback storage.​
  • ARCHIVE: archive storage.​
  • COLD_ARCHIVE: cold archive storage.​
  • DEEP_COLD_ARCHIVE: deep cold archive storage.​
Last updated: 2025.10.11 17:59:24