Elastic Compute Service
Local volume type | Matching ECS instance type family | Scenarios |
Local volume type | Matching ECS instance type family | Scenarios |
Local NVMe SSD |
| Assume that the ECS instance type family is local SSD, local NVMe SSDs are applicable for the following scenarios: Business scenarios involving I/O-intensive applications that feature high availability architecture at the application layer, such as relational databases, NoSQL, and ElasticSearch. |
Local SATA HDD | Big Data | Local SATA HDDs are applicable for big data services involving large-scale data storage and offline computing tasks, such as EMR. These services are inherently insensitive to latency and can tolerate SPOFs because data redundancy is enabled on the upper layer. |
NVMe SSD metric | ecs.i4ag.12xlarge | ecs.i4ag.16xlarge | ecs.i4ag.24xlarge | ecs.i4ag.32xlarge | ecs.i4ag.48xlarge |
NVMe SSD metric | ecs.i4ag.12xlarge | ecs.i4ag.16xlarge | ecs.i4ag.24xlarge | ecs.i4ag.32xlarge | ecs.i4ag.48xlarge |
Maximum read IOPS (10,000) | 270 | 270 | 540 | 540 | 1,080 |
Maximum read throughput (GB/s) | 13 | 13 | 26 | 26 | 52 |
Maximum write throughput (GB/s) | 5.5 | 5.5 | 11 | 11 | 22 |
NVMe SSD metric | ecs.i3s.3xlarge | ecs.i3s.6xlarge | ecs.i3s.12xlarge | ecs.i3s.24xlarge | ecs.i3s.48xlarge |
NVMe SSD metric | ecs.i3s.3xlarge | ecs.i3s.6xlarge | ecs.i3s.12xlarge | ecs.i3s.24xlarge | ecs.i3s.48xlarge |
Maximum read IOPS (10,000) | 100 | 200 | 400 | 800 | 1,600 |
Maximum read throughput (GB/s) | 6.5 | 13 | 26 | 52 | 104 |
Maximum write throughput (GB/s) | 3.5 | 7 | 14 | 28 | 56 |
NVMe SSD metric | ecs.i2g.2xlarge | ecs.i2g.4xlarge | ecs.i2g.8xlarge | ecs.i2g.12xlarge | ecs.i2g.14xlarge | ecs.i2g.16xlarge | ecs.i2g.28xlarge |
NVMe SSD metric | ecs.i2g.2xlarge | ecs.i2g.4xlarge | ecs.i2g.8xlarge | ecs.i2g.12xlarge | ecs.i2g.14xlarge | ecs.i2g.16xlarge | ecs.i2g.28xlarge |
Maximum read IOPS (10,000) | 32 | 64 | 128 | 192 | 256 | 256 | 512 |
Maximum read throughput (GB/s) | 1.6 | 3.2 | 6.4 | 9.6 | 12.8 | 12.8 | 25.6 |
Maximum write throughput (GB/s) | 0.7 | 1.4 | 2.8 | 4.2 | 5.6 | 5.6 | 11.2 |
NVMe SSD metric | ecs.i2.3xlarge | ecs.i2.4xlarge | ecs.i2.8xlarge | ecs.i2.14xlarge | ecs.i2.28xlarge |
NVMe SSD metric | ecs.i2.3xlarge | ecs.i2.4xlarge | ecs.i2.8xlarge | ecs.i2.14xlarge | ecs.i2.28xlarge |
Maximum read IOPS (10,000) | 75 | 75 | 150 | 300 | 600 |
Maximum read throughput (GB/s) | 6.5 | 6.5 | 13 | 26 | 52 |
Maximum write throughput (GB/s) | 3.3 | 3.3 | 6.6 | 13.2 | 26.4 |
SATA HDD metric | ecs.d4c.4xlarge | ecs.d4c.7xlarge | ecs.d4c.14xlarge/ecs.d4cd.14xlarge | ecs.d4c.28xlarge/ecs.d4cd.28xlarge |
SATA HDD metric | ecs.d4c.4xlarge | ecs.d4c.7xlarge | ecs.d4c.14xlarge/ecs.d4cd.14xlarge | ecs.d4c.28xlarge/ecs.d4cd.28xlarge |
HDD quantity (volume) | 3 | 6 | 12 | 24 |
Maximum throughput (MiB/s) | 770 | 1540 | 3080 | 6160 |
Maximum capacity (GB) | 24 | 48 | 96 | 192 |
SATA HDD metric | ecs.d4s.4xlarge | ecs.d4s.7xlarge | ecs.d4s.14xlarge/ecs.d4sd.14xlarge | ecs.d4s.28xlarge/ecs.d4sd.28xlarge |
SATA HDD metric | ecs.d4s.4xlarge | ecs.d4s.7xlarge | ecs.d4s.14xlarge/ecs.d4sd.14xlarge | ecs.d4s.28xlarge/ecs.d4sd.28xlarge |
HDD quantity (volume) | 3 | 6 | 12 | 24 |
Maximum throughput (MiB/s) | 815 | 1630 | 3260 | 6520 |
Maximum HDD capacity (GB) | 72 | 144 | 288 | 576 |