This topic describes how to create and manage VCI image caches by using CustomResourceDefinition (CRD) resources in Kubernetes.​
Prerequisites​
  • The container image required to create the VCI has been prepared. You can use images from Volcano Engine CR as well as images from third-party container registries. To upload an image to CR, see Pushing and pulling images.​
Create a VCI image cache based on ImageCache​
  1. Create a custom resource ImageCache that will be used to create the VCI image cache. The following imagecache-test.yaml file serves as an example:​
  • ​
    apiVersion: vci.volcengine.com/v1beta1​
    kind: ImageCache​
    metadata:​
    name: imagecache-test # Specify the name of the ImageCache. The name must be unique within the cluster.​
    spec:​
    images: # List of container images required to create the image cache.​
    - cr-cn-beijing.volces.com/vke/centos:v1​
    - cr-cn-beijing.volces.com/vke/busybox:v1​
    imagePullSecrets: # List of CR access credential Secrets. If not configured, a temporary key will be obtained.​
    - default:secret1​
    subnetIds: # List of IDs of subnets to which the image cache belongs.​
    - subnet-3rf6vwb******​
    - subnet-7s89a78******​
    securityGroupIds: # List of IDs of security groups to which the image cache belongs.​
    - sg-2byy13cns******​
    - sg-ds89xas98******​
    retentionDays: 7 # Image cache retention duration. Unit: days. An expired image cache will be cleared.​
    volume:​
    imageCacheSize: 40 # Size of the image cache. Unit: GiB.​
    prewarmZoneIds: # The warm-up policy configurations of the EBS snapshots that correspond to the image cache. Specify the availability zone for the snapshot to be warmed up.​
    - cn-beijing-b​
    - cn-beijing-c​
    prewarmRetentionDays: 90 # The warm-up retention duration for the EBS snapshots that correspond to the image cache. Unit: day(s). Value range: 1–180.​
    ​
  1. Run the following command to create the ImageCache.​
  • ​
    kubectl create -f imagecache-test.yaml​
    ​
Associating an existing VCI image cache by using ImageCache​
  1. Create a custom resource ImageCache and associate it with an existing VCI image cache. The following imagecache-exist.yaml file serves as an example:​
  • ​
    apiVersion: vci.volcengine.com/v1beta1​
    kind: ImageCache​
    metadata:​
    name: imagecache-exist # Specify the name of the ImageCache. The name must be unique within the cluster.​
    spec: ​
    appointedImageCacheId: imc-****** # The ID of the existing image cache.​
    securityGroupIds: # List of security group IDs for the network of the image cache.​
    - sg-2byy13cns******​
    subnetIds: # List of IDs of subnets to which the image cache belongs.​
    - subnet-3rf6vwb******​
    - subnet-7s89a78******​
    ​
  1. Run the following command to create the ImageCache.​
  • ​
    kubectl create -f imagecache-exist.yaml​
    ​
Querying ImageCache status and latest details​
After a VCI image cache is created, the ImageCache Controller will obtain the latest information of the image cache and synchronize it to the description of the ImageCache. You can run the get ImageCache command to get the latest status and information of the image cache.​
tip​
  • The status of the image cache after creation will be written back to the status field of the corresponding ImageCache custom resource.​
  • If the image cache information is updated via the UpdateImageCache API, the information of the corresponding ImageCache resource will also be refreshed.​
  • When the image cache is deleted or cleaned up, the status of the custom resource object is updated. The custom resource object is not deleted.​
The following content provides an example of the custom resource ImageCache.​
​
apiVersion: vci.volcengine.com/v1beta1​
kind: ImageCache​
metadata:​
name: imagecache-test # Name of the ImageCache.​
spec:​
images: # List of container images required to create the image cache.​
- cr-cn-beijing.volces.com/vke/centos:v1​
- cr-cn-beijing.volces.com/vke/busybox:v1​
imagePullSecrets: # List of CR access credential secrets.​
- default:secret1​
subnetIds: # List of IDs of subnets to which the image cache belongs.​
- subnet-3rf6vwb******​
- subnet-7s89a78******​
securityGroupIds: # List of IDs of security groups for the network of the image cache.​
- sg-2byy13cns******​
- sg-ds89xas98******​
retentionDays: 7 # Image cache retention duration. Unit: days. An expired image cache will be cleared.​
volume:​
imageCacheSize: 40 # Size of the image cache. Unit: GiB.​
prewarmZoneIds: # EBS snapshot warm-up policy configuration for the image cache (the availability zone of the snapshot).​
- cn-beijing-b​
- cn-beijing-c​
prewarmRetentionDays: 90 # The warm-up retention duration for the EBS snapshots that correspond to the image cache. Unit: days.​
status:​
images:​
previous: # Image information configured in .spec last time, used for comparison with the current .spec.​
- cr-cn-beijing.volces.com/vke/centos:v1​
- cr-cn-beijing.volces.com/vke/busybox:v1​
latest: # Latest image information synchronized based on EventRuleRecords.​
- cr-cn-shanghai.volces.com/vke/centos:v2​
- cr-cn-shanghai.volces.com/busybox:v2​
imageCacheName: imagecache-test-******​
imageCacheId: ********* # Image cache ID.​
creationTime: 2024-04-16T20:33:54Z # Creation time of the image cache.​
updateTime: 2024-04-16T20:33:54Z # Time when the image cache was last updated.​
expireDateTime: 2024-07-16T20:33:54Z # The time when the image cache expires.​
lastMatchedTime: 2024-04-16T21:23:54Z # Time when the image cache was last matched.​
phase: Ready # Image cache status information.​
conditions:​
- lastTransitionTime: "2024-04-16T20:33:54Z"​
message: instance imc-3vknvu66783****** has been ready​
reason: ImageCacheHasBeenReady​
status: "True"​
type: ImageCacheReady​
- lastTransitionTime: "2024-04-16T20:33:54Z"​
message: "instance {imc-******} is in progress"​
reason: CreateImageCacheRequestSuccess​
status: "True"​
type: CreationInProgress​
​
Deleting VCI image caches via ImageCache​
When you delete the ImageCache resource using the delete command, the ImageCache Controller will also delete the corresponding VCI image cache.​
The following example command deletes a resource ImageCache named imagecache-test. After the command is executed, the VCI image cache corresponding to imagecache-test will be deleted.​
​
kubectl delete imc imagecache-test​
​
Updating VCI image caches via ImageCache​
When you update an ImageCache resource, the ImageCache Controller will also update the corresponding VCI image cache.​
tip​
  • When the status of the image cache is Ready, you must modify the images field (other fields can also be modified) to trigger the image cache update.​
  • When the status of the image cache is Failed, modifying any updatable field in the YAML below will trigger an image cache update.​
For a list of fields that support updates, see the comments in the YAML file below (except for fields with the comment It cannot be updated, all other fields with comments support updates).​
​
apiVersion: vci.volcengine.com/v1beta1​
kind: ImageCache​
metadata:​
name: imagecache-test # Name of the ImageCache. It cannot be updated.​
spec:​
images: # List of container images required to create the image cache.​
- cr-cn-beijing.volces.com/vke/centos:v1​
- cr-cn-beijing.volces.com/vke/busybox:v1​
imagePullSecrets: # List of container registry access credentials. If no credentials are provided, temporary credentials will be obtained.​
- default:secret1​
subnetIds: # List of IDs of subnets to which the image cache belongs.​
- subnet-3rf6vwbgkg****​
- subnet-7s89a78xaa****​
securityGroupIds: # List of IDs of security groups for the network of the image cache.​
- sg-2byy13cnsczy****​
- sg-ds89xas98sa9****​
retentionDays: 7 # Image cache retention duration. Unit: days. It cannot be updated.​
volume:​
imageCacheSize: 40 # Size of the image cache. Unit: GiB.​
prewarmZoneIds: # EBS snapshot warm-up policy configuration for the image cache. Specify the availability zone for the snapshot to be warmed up.​
- cn-beijing-b​
- cn-beijing-c​
prewarmRetentionDays: 90 # The warm-up retention duration for the EBS snapshots that correspond to the image cache. Unit: day(s). Value range: 1–180.​
​
Automatically updating VCI image caches based on event notifications​
When creating an ImageCache corresponding to a VCI image cache, you can configure CR event notification rules to enable automatic updates of the VCI image cache based on event notifications.​
  1. Create an ImageCache corresponding to the VCI image cache and configure CR event notification rules. The following imagecache-test.yaml file serves as an example:​
  • ​
    apiVersion: vci.volcengine.com/v1beta1​
    kind: ImageCache​
    metadata:​
    name: imagecache-test # Specify the name of the ImageCache. The name must be unique within the cluster.​
    spec:​
    eventRule: # Create CR event notification rules.​
    strategy: update # Strategy in case of a match. Values include update and new, indicating an image cache update and creation, respectively.​
    registry: "helm-cr" # CR instance name. Only Standard Edition instances are supported.​
    namespaces: # List of namespaces within the CR instance.​
    - vke​
    images: # List of images within the namespace.​
    - centos ​
    - busybox​
    tag: ".*" # Rule scope. Regular expressions are supported.​
    enabled: true # Whether to enable eventRule. Values: true (enabled) and false (disabled).​
    images: # List of container images required to create the image cache.​
    - cr-cn-beijing.volces.com/vke/centos:v1​
    - cr-cn-beijing.volces.com/vke/busybox:v1​
    imagePullSecrets: # List of container registry access credentials. If no credentials are provided, temporary credentials will be obtained.​
    - default:secret1​
    subnetIds: # List of IDs of subnets to which the image cache belongs.​
    - subnet-3rf6vwb******​
    - subnet-7s89a78******​
    securityGroupIds: # List of IDs of security groups for the network of the image cache.​
    - sg-2byy13cns******​
    - sg-ds89xas98******​
    retentionDays: 7 # Image cache retention duration. Unit: days. An expired image cache will be cleared.​
    volume:​
    imageCacheSize: 40 # Size of the image cache. Unit: GiB.​
    prewarmZoneIds: # EBS snapshot warm-up policy configuration for the image cache. Specify the availability zone for the snapshot to be warmed up.​
    - cn-beijing-b​
    - cn-beijing-c​
    prewarmRetentionDays: 90 # The warm-up retention duration for the EBS snapshots that correspond to the image cache. Unit: day(s). Value range: 1–180.​
    ​
  1. Run the following command to create the ImageCache.​
  • ​
    kubectl create -f imagecache-test.yaml​
    ​
  • The following sample code provides an example of the status field returned when you query the ImageCache containing CR event notification rules. For information about how to query the information, see Querying ImageCache status and latest details.​
  • ​
    status:​
    notifications: # Record EventRuleRecords messages.​
    - image: "cr-cn-shanghai.volces.com/vke/centos:v3"​
    receviedTimestamp: 2024-05-27T10:33:30Z​
    processedTimestamp: 2024-05-27T10:34:30Z​
    id: "xx-4"​
    - image: "cr-cn-shanghai.volces.com/vke/busybox:v3"​
    receviedTimestamp: 2024-05-27T10:33:30Z​
    processedTimestamp: 2024-05-27T10:34:30Z​
    id: "xx-1"​
    eventRuleStatus:​
    ruleName: ****** # The name of the CR event notification rule.​
    ruleId: "******" # The ID of the event notification rule.​
    updateTime: 2024-05-27T09:23:56Z # Time of last update on the event notification rule.​
    eventRuleHash: "******"​
    images:​
    previous: # Image information configured in .spec last time, used for comparison with the current .spec.​
    - cr-cn-shanghai.volces.com/vke/centos:v1​
    - cr-cn-guilin-boe.cr.volces.com/busybox:v1​
    latest: # Latest image information synchronized based on EventRuleRecords.​
    - cr-cn-shanghai.volces.com/vke/centos:v2​
    - cr-cn-guilin-boe.cr.volces.com/busybox:v2​
    imageCacheName: ********* # Image cache name.​
    imageCacheId: ********* # Image cache ID.​
    creationTime: 2024-05-27T10:33:30Z # Creation time of the image cache.​
    updateTime: 2024-05-27T10:33:30Z # Time when the image cache was last updated.​
    expireDateTime: 2024-05-27T10:33:30Z # The time when the image cache expires.​
    lastMatchedTime: 2024-05-27T09:33:30Z # Time when the image cache was last matched.​
    phase: Failed # Image cache status information.​
    conditions:​
    - lastTransitionTime: "2024-04-16T20:33:54Z"​
    message: instance imc-3vknvu667****** has been ready​
    reason: ImageCacheHasBeenReady​
    status: "True"​
    type: ImageCacheReady​
    - lastTransitionTime: "2024-04-16T20:33:54Z"​
    message: "instance {imc-******} is in progress"​
    reason: CreateImageCacheRequestSuccess​
    status: "True"​
    type: CreationInProgress​
    ​