Parameter | Description |
Parameter | Description |
Name | Specify a name for the StorageClass. The name must be unique within the cluster. |
StorageClass type | Select the storage type. In this scenario, select EFS. |
Access type | Select an access type for the PV. In this scenario, select FSX. |
Availability zone | AZs refer to physical areas isolated from each other in terms of electricity and network in the same region. AZs communicate with each other over internal networks. |
Billing type | The billing method for resources. Pay-as-you-go is supported. |
Project | Assign the StorageClass to a project so that you can perform operations such as maintenance and authorization at the project level. By default, the default project is selected. For details, see Project management. |
Access point | Select the created EFS file system and access point. |
Mount path | Configure the file system mount path. The system will create subdirectories for dynamic PVs under this directory. Make sure that the entered mount path already exists. By default, the root directory (/) is used. |
PersistentVolume binding mode | Select a PV binding mode.
|
Advanced settings | |
Mount parameters | Specify PV mount parameters, which support dynamic modification and only take effect on newly mounted disks instead of those already mounted. For details, see Specifying mount parameters. |
Parameter | Description |
Parameter | Description |
Namespace | Select the namespace to which the PVC belongs. We recommend selecting a custom namespace or the system-created default namespace. For details about namespaces, see Namespace overview. |
Name | Specify a name for the PVC. The name must be unique within the cluster. |
StorageClass type | Select a storage type. In this scenario, select EFS. |
Access mode | Select a PVC access mode. You can select ReadWriteMany, which enables read and write access by multiple nodes. |
Creation method | Configure the method for creating a PVC. In this scenario, select Create based on StorageClass. |
StorageClass | Select the created SC. |
Capacity | Configure the PV capacity in Gi. |
Parameter | Description |
Parameter | Description |
provisioner | The driver required for PV mount. In this topic, you need to set the value to fsx.csi.volcengine.com, which indicates the csi-fsx add-on. |
type | The file system type. In this example, set the value to efs to specify EFS. |
fsid | The ID of the created EFS file system. tip You can view the ID of the created file system in the console. For details, see Viewing file system information. |
server | The ID and domain name of the access point that has been created in the EFS file system, such as ap-df81***.cnbja5ef***.3pspvsoy8hy***.cn-beijing.efs.ivolces.com. |
subpath | The mount path of EFS. The system will create subdirectories for dynamic PVs under this directory. Make sure that the entered mount path already exists. By default, the root directory (/) is used. |
mountOptions | Configure PV mount parameters, which support dynamic modification and only take effect on newly mounted PVs instead of those already mounted. For details, see Specifying mount parameters. |
reclaimPolicy | The PV reclaim policy. Only Retain is supported. It indicates that when you delete the PVC, the PV and the data in the PV will not be simultaneously deleted. You need to manually delete them. |
volumeBindingMode | The binding mode of the PV. Values:
|
Parameter | Description |
Parameter | Description |
accessModes | The PVC access mode. You can only select ReadWriteMany, which enables read and write access by multiple nodes. |
storage | The declared storage capacity in Gi. The value is an integer within the range of 1 to 16384. |
storageClassName | The name of the created SC. |
volumeMode | The PV types. Valid values:
|