Volcengine Kubernetes Engine (VKE) can use Remote Direct Memory Access (RDMA) resources through add-ons to eliminate bottlenecks of computing tasks brought by traditional network communication. This topic introduces how a VKE cluster uses RDMA resources provided by RDMA over Converged Ethernet (RoCE) high-performance compute (HPC) clusters.
tip
[public beta]: VKE clusters featured with access to RDMA resources are currently in public beta.
Background information
- RDMA is a high-performance network protocol that reduces CPU usage and memory bandwidth bottlenecks, as well as improves bandwidth utilization. It comes with the following advantages:
- Zero Copy: Applications can transfer data without involving the network software stack, allowing data to be directly sent to the buffer or directly received from the buffer without being copied to the network layer.
- Kernel Bypass: RDMA provides a proprietary Verbs interface, allowing applications to transfer data directly from user space without switching context between kernel and user modes.
- CPU Offload: Applications can access memory on remote hosts without consuming any CPU there. Remote memory will be read without any help from remote processes (or CPUs), and the content read from them will not be written into the remote CPU caches.
- The High Performance Compute (HPC) cluster is a cluster computing environment used to handle large-scale computing tasks, usually composed of a large number of compute nodes interconnected by an RDMA high-speed network. It supports both RoCE and InfiniBand.
- An HPC cluster can provide powerful computing capability, large memory, high-speed storage, and networks to meet the demands of compute-intensive, data-intensive, or combined workloads. In an HPC cluster, computing tasks are assigned to each compute node for parallel processing, fully utilizing the computing power of multiple nodes to accelerate computation and improve efficiency. For details, see HPC cluster overview.
In the RoCE network mode, the RDMA add-on supports the following modes. The following table describes different modes and their usage restrictions.
tip
If your pods need to use HostNetwork, we recommend that you use RDMA resources provided by open source add-ons. For details, see the open source documentation. Usage instructions
The following document introduces the officially proven practices. To achieve the expected results and comply with the Volcengine Kubernetes Engine (VKE) Limits, you need to strictly follow the procedures (or operate on the recommended resources) in this document. If you want to use another solution, consult your account manager. Usage limits
- A pod cannot use mGPU and RDMA add-ons simultaneously.
- RDMA devices can be used only in clusters with the VPC-CNI network model, and the vpc-cni add-on must be upgraded to v1.7.1 or later version.
- The Kubernetes version of the cluster must meet the following requirements: If the cluster version is outdated, upgrade it first. For details, see Upgrading clusters.
- If a NCCL network error occurs in an environment running RDMA, please refer to FAQ for solutions.
Procedure: Create resources (recommended)
We recommend that you use RDMA resources when you create a VKE cluster and node pool. The detailed steps are as follows.
Step 1: Create an HPC cluster
- Click Create HPC cluster and finish configurations based on the parameter descriptions in the table below.
Step 2: Create a cluster and prepare resources
tip
This step only covers the key parts of configuring RDMA resources, such as creating a node pool, adding node labels, setting Kubelet custom parameters, and installing RDMA add-ons. For how to create and configure a cluster, see Creating clusters. - In the left navigation pane, click Cluster. Click Create cluster and specify the required parameters.
- The table below contains instructions as well as descriptions of key parameters in this step. Please follow the instructions in the table and configure the rest as needed.
- On the Node pool configuration (optional) page, you need to finish key configurations, including settings of a new node pool, node labels, and Kubelet custom parameters. Click Next: Addon configuration when you finish all necessary settings on this page.
- The table below contains instructions as well as descriptions of key parameters in this step. Please follow the instructions in the table and configure the rest as needed.
- In the Addon configuration step, select the rdma-device-plugin add-on and configure other add-ons based on your business requirements. Click Next: Confirm Configuration to go to the next page.
- After confirming that the cluster information and billing details are correct, read the Volcengine Kubernetes Engine Specific Terms of Service, select the checkbox to accept them, and then click Confirm to start creating the cluster.
Step 3: Use RDMA Resources
After the cluster is created, RDMA resources can be used when workloads are being created. In this scenario, a Deployment is used as an example.
Configuring through the console
Configuring through YAML
- Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane of the cluster management page, click Workload > Deployment to go to the Deployment management page.
- Click Create Deployment. In the ResourceQuota section in the Container configuration step, specify the number of RDMA cards based on your business requirements. For the descriptions of other parameters, see Creating Deployments.
warning
- When the RDMA mode is exclusive, shared, or shared-multi (1:N shared), we recommend that you set the number of RDMA cards to the total number of cards in the host or half the number to achieve optimal performance for GPU training or inference tasks. For example, when the host has four RDMA NICs, you can set the number of RDMA cards to 2 or 4. When the system has eight RDMA NICs, you can set the number of RDMA cards to 4 or 8.
- You can use the shared-host mode if you do not want to be concerned about the number of RDMA NICs. You cannot configure the shared-host mode in the console. To use this mode, you can configure it by using the YAML configuration based on the following instructions.
- When the RDMA mode is exclusive, shared, or shared-multi (1:N shared), execute the following YAML code to configure RDMA resources for the pod.
- In the spec.containers.resources field, use vke.volcengine.com/rdma to apply for RDMA NIC for the pod.
- In the pod annotation, use k8s.volcengine.com/pod-networks to specify the number of NICs. We recommend setting the number of RDMA cards to the total number of cards in the host, or half the number to achieve optimal performance for GPU training or inference tasks. For example, when the host has four RDMA NICs, you can set the number of RDMA cards to 2 or 4. When the system has eight RDMA NICs, you can set the number of RDMA cards to 4 or 8.
- In most cases, you need to use the spec.containers.securityContext field to request the IPC_LOCK privilege.
- The preceding sample code provides an example of how to automatically create an RDMA NIC. To create multiple RDMA NICs, copy the code block in k8s.volcengine.com/pod-networks multiple times.
- When the RDMA mode is shared-host, execute the following YAML code to configure RDMA resources for the pod.
- In the spec.containers.resources field, use vke.volcengine.com/rdma-host to apply for the RDMA resources of the entire host for the pod. The value is 1 and cannot be changed.
- In the pod annotation, use k8s.volcengine.com/pod-networks to specify the number of NICs. Differing from other modes, the shared-host mode allows you to configure only one code block. If you configure more than one code block, an error will occur.
- In most cases, you need to use the spec.containers.securityContext field to request the IPC_LOCK privilege.
When you run NCCL in the container in shared mode, you need to explicitly specify the NCCL_IB_GID_INDEX environment variable. You can execute the source nccl_env.sh command to obtain the RDMA environment variables. The content of the sample script nccl_env.sh for dynamically obtaining NCCL environment variables is as follows.
warning
Make sure that the configuration of NCCL_IB_GID_INDEX is valid. You can execute the show_gids command to obtain the gid index for RoCE v2 IPv4. The script invoked by the show_gids command is available on the host.
Procedure: Existing resources
If you have already created a VKE cluster and node pool, you can directly use RDMA resources in the existing VKE cluster and node pool by performing the following steps.
Step 1: Install the RDMA device add-on
- Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane, click Addons. Find the rdma-device-plugin add-on on the Network tab.
- Move the pointer over the add-on card and click Deploy to install the RDMA device add-on in the cluster.
Step 2: Prepare node resources
Prepare nodes that support RDMA devices, such as High Performance Computing Optimized nodes. You can create nodes or use existing nodes that meet your business requirements. Manually add the label vke.node.rdma.mode: {value} to configure the RDMA usage mode for nodes or the node pool. The following modes are available: exclusive, shared, shared-multi, and shared-host.
warning
- Except for ecs.hpcg1ve.21xlarge and North-China ecs.hpcpni2.28xlarge, we recommend that you select the shared mode for instance types.
- If you switch the RDMA mode by modifying the label, make sure that all existing workloads have finished running, and restart the nodes to make the new mode take effect.
Step 1: Add a label to an existing node
- Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane, click Nodes > Node. Find the target node and in the Actions column, click ... > Label management.
- Click Add new to add the preceding label to the existing node. Then, click Confirm to save the configurations.
- The following sample code shows the YAML content.
Method 2: Add node labels to the node pool
- Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane, click Nodes > Node pool to create a node pool, or click Edit in the Actions column that corresponds to the target cluster. Add node labels to the node pool and then click Confirm to save the configurations.
Step 3: Modify the kubelet topology management policy of the node
The node kubelet topology management policy varies based on the RDMA mode.
- If the RDMA mode is exclusive, shared, or shared-multi (1:N shared), you need to configure a node kubelet topology management policy and add the custom parameter topologyManagerPolicy: best-effort. This ensures that GPU and RDMA can be allocated to the same NUMA node.
- When the RDMA mode is shared-host, you do not need to configure a node kubelet topology management policy.
danger
When you modify custom kubelet parameters for an existing node pool, the configurations only take effect on new nodes and do not apply to existing nodes by default. To apply changes to existing nodes, you need to synchronize the configurations for existing nodes. For details, see Existing node configuration synchronization. - Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane, click Nodes > Node pool to go to the node pool management page.
- Click the name of the target node pool. On the Kubelet configs tab, click Edit in the upper-right corner to manually add parameters. Then, click Confirm to save the configurations.
- The following sample code shows the YAML content.
Step 4: Use RDMA resources
After the configurations are complete, RDMA resources can be used when workloads are being created. In this scenario, a Deployment is used as an example.
Configuring through the console
Configuring through YAML
- Log in to the VKE console. Click the name of the target cluster to go to the cluster management page.
- In the left navigation pane of the cluster management page, click Workload > Deployment to go to the Deployment management page.
- Click Create Deployment. In the ResourceQuota section in the Container configuration step, specify the number of RDMA cards based on your business requirements. For other workload configurations, see Creating Deployments.
warning
- When the RDMA mode is exclusive, shared, or shared-multi (1:N shared), we recommend that you set the number of RDMA cards to the total number of cards in the host or half the number to achieve optimal performance for GPU training or inference tasks. For example, when the host has four RDMA NICs, you can set the number of RDMA cards to 2 or 4. When the system has eight RDMA NICs, you can set the number of RDMA cards to 4 or 8.
- You can use the shared-host mode if you do not want to be concerned about the number of RDMA NICs. You cannot configure the shared-host mode in the console. To use this mode, you can configure it by using the YAML configuration based on the following instructions.
- When the RDMA mode is exclusive, shared, or shared-multi (1:N shared), execute the following YAML code to configure RDMA resources for the pod.
- In the spec.containers.resources field, use vke.volcengine.com/rdma to apply for RDMA NIC for the pod.
- In the pod annotation, use k8s.volcengine.com/pod-networks to specify the number of NICs. We recommend setting the number of RDMA cards to the total number of cards in the host, or half the number to achieve optimal performance for GPU training or inference tasks. For example, when the host has four RDMA NICs, you can set the number of RDMA cards to 2 or 4. When the system has eight RDMA NICs, you can set the number of RDMA cards to 4 or 8.
- In most cases, you need to use the spec.containers.securityContext field to request the IPC_LOCK privilege.
- The preceding sample code provides an example of how to automatically create an RDMA NIC. To create multiple RDMA NICs, copy the code block in k8s.volcengine.com/pod-networks multiple times.
- When the RDMA mode is shared-host, execute the following YAML code to configure RDMA resources for the pod.
- In the spec.containers.resources field, use vke.volcengine.com/rdma-host to apply for the RDMA resources of the entire host for the pod. The value is 1 and cannot be changed.
- In the pod annotation, use k8s.volcengine.com/pod-networks to specify the number of NICs. Differing from other modes, the shared-host mode allows you to configure only one code block. If you configure more than one code block, an error will occur.
- In most cases, you need to use the spec.containers.securityContext field to request the IPC_LOCK privilege.
When you run NCCL in the container in shared mode, you need to explicitly specify the NCCL_IB_GID_INDEX environment variable. You can execute the source nccl_env.sh command to obtain the RDMA environment variables. The content of the sample script nccl_env.sh for dynamically obtaining NCCL environment variables is as follows.
warning
Make sure that the configuration of NCCL_IB_GID_INDEX is valid. You can execute the show_gids command to obtain the gid index for RoCE v2 IPv4. The script invoked by the show_gids command is available on the host.
Viewing information about RDMA NIC
After you create a pod and configure RDMA resources, you can view the RDMA NIC mounted to the pod in the console or in YAML. This topic provides an example of how to view NIC information in the console.
- Click the name of the target pod to go to the pod details page.
- Click the Overview tab. In the Networking section, you can view the information about the RDMA NIC mounted to the pod.
- In the upper right corner of the pod details page, click ... > Edit Yaml to view the YAML configuration of the pod. You can view information about the RDMA NIC mounted to the pod, such as the IP address and MAC address.
warning
When the RDMA add-on mode is exclusive, the RDMA NIC on the host is in the Down state.